Thunderstone Standard Specifications for Architectural Cast Stone Products

All Thunderstone manufacturing and product testing follows the specifications as defined by the ASTM Specification C 1364 – 06 for Architectural Cast Stone. A number of these specifications related to the physical requirements of our products are listed below;

Compressive strength: not less than 6500 p.s.i after 28 days / ASTM C 1194
Rate of Absorption: not greater than 6% after 28 days / ASTM C 1195
Air Content: 4-8% for units exposed to freeze-thaw environments / ASTM C 173
Resistance to Freeze/Thaw: less than 5% CPWL after 300 cycles / ASTM C 1364
Linear Shrinkage: shrinkage shall not exceed 0.065% / ASTM C 426

Portland Cement: ASTM Specification C 150
Aggregates: ASTM Specification C 33
Pigments: ASTM Specification C 979
Admixtures: ASTM Specification C 494
Reinforcement: ASTM Specification A 615 / A 615M

Compressive Strength Test Method: ASTM Specification C 1194
Rate of Absorption Test Method: ASTM Specification C 1195
Resistance to Freeze / Thaw Test Method: ASTM Specification C 666

 

 

 